17Lf Servo Series Actuators
17Lf Series mightyZAP Firmware Update - V1.0.3 (Sep, 13, 2024 release)
Firmware
Author
irrobot
Date
2024-09-13 16:05
Views
802
Firmware for 17Lf has been updated to V1.1.0, so please ignore below announcement. Please get the latest firmware here.
We are pleased to release updated firmware for the new 17Lf series Actuators. (bug fix)
[Update details - Actuator firmware V1.0.3]
The end.
We are pleased to release updated firmware for the new 17Lf series Actuators. (bug fix)
[Update details - Actuator firmware V1.0.3]
- Modified so that it cannot be saved with ID '0'
- Modified so that it cannot be saved when ID, Baudrate exceeds the limit value
- Please use TOTAL Manager software (latest V0.9.8) for 17Lf firmware update. (old Manager software is not compatible with 17Lf series) [Total Manager software / Update manual download]
- Prepare for IR-USB02 PC USB interface to connect your 17Lf actuator with the Total Manager software for firmware update.
- Make sure to install the correct firmware that matches the model name of your actuator. Please pay close attention to the model name and download the exact update file.
- If the old firmware has been already applied to your existing equipment, be sure to test the new firmware with the equipment for verification. Although the actuator specifications are not to be changed through firmware update, the operating characteristics may be affected depending on the characteristics of the equipment, so please be sure to test the actuator with the new firmware in the equipment.
- Make sure to download correct model named firmware for your mightyZAP. Download the concerned firmware correctly according to your actuator model.
- Update single actuator only. Do not update with multiple qty of servo actuators under the serial connection(daisy chain) at the same time. Otherwise, it may occur some error.
- In case that incorrect firmware is installed, please process the update with correct firmware update file again.
- Before update, make sure if all wirings (communication wire, power wire) are properly connected between IR-USB01(or USB02) & actuator / between PC and IR-USB01(or USB02). Then, please do not touch them while updating as it may occur fatal communication error. Please contact factory if communication or update error continues.
Stroke | Model | Old Version | New Version | Firmware download link (click model name) |
27mm | 17Lf-20F-27 | V1.0.2 | V1.0.3 | 17Lf-20F-27 |
17Lf-35F-27 | 17Lf-35F-27 | |||
17Lf-70F-27 | 17Lf-70F-27 | |||
37mm | 17Lf-17F-37 | 17Lf-17F-37 | ||
17Lf-27F-37 | 17Lf-27F-37 | |||
17Lf-50F-37 | 17Lf-50F-37 | |||
50mm | 17Lf-17F-50 | 17Lf-17F-50 | ||
17Lf-27F-50 | 17Lf-27F-50 | |||
17Lf-50F-50 | 17Lf-50F-50 | |||
87mm | 17Lf-17F-87 | 17Lf-17F-87 | ||
17Lf-27F-87 | 17Lf-27F-87 | |||
17Lf-50F-87 | 17Lf-50F-87 |
Total 14