Support
mightyZAP, the micro linear servo actuating solution
for the era of the 4th industrial revolution
FAQ
-
Force Can I adjust the Force?
Using “Motor operating rate” parameter, Stall force level can be adjusted, and speed will be adjusted at the same time.
The stall force is the maximum force of the motor at stall condition and it is 5 times bigger than Rated force.
And please be advised that Rated force will not be changed at any time.
For example, in case of L12-20F-3, its rated force is 20N and the rated force 20N will be maintained regardless motor operating rate.
Use actuator within Rated force range. -
Force Can I use mightyZAP at Z axis? (vertically)
Yes, you can. But, Z axis force is slightly different from its rated force, so please refer to the specification chart. And it is highly recommended to apply “Force Off” command after the rod is positioned so that concerned position can be hold by mechanical frictional force. In this case, motor power will be off while communication is still alive. Please refer to the user manual for more detailed information. -
Force What is rated force? Is it maximum force of mightyZAP?